JINDAL Biological Safety Cabinet Class II type A2 for cell culture applications which is ergonomically designed with low noise features. The safety cabinet offers a high level of HEPA filter efficiency of 99.990% efficiency at 0.3 µm particle & an airflow pattern of 70% air recirculation and 30% exhaust. Stand height is 28 inches.

The Cabinet outer body is made of galvanized steel with powder coating finish material. The Cabinet work bench is made of single stainless steel 304 grade material. The side wall made of stainless steel 304 grade material.

The Cabinet is equipped with a smart, safe and user-friendly digital display system that protects the operator and provides alerts for periodic maintenance actions and parts’ replacement. The cabinet has safety reasons for the user & the environment and accessories is supplied with each cabinet Foot operated burner, canopy to connect external duct.

The cabinet is precisely control ventilation to sweep airborne particles produced during routine microbiological procedures way from the user while maintaining a controlled environment for the specimen. The Bio safety cabinet has consistent and reliable down flow velocity across the supply HEPA filter over the life of the cabinet. The cabinet has a pressure sensor for detect pressure drop across the supply filter rather than at just one point across the down flow. Pressure sensor encased to protect the sensor from temperature, humidity and other environmental phenomena that impact the sensor’s performance. The cabinet has stable and self-compensating airflow, despite building voltage fluctuations & filter loading.

The system also has a programmable “standby” mode that shuts down all unnecessary electricity consumption and sets vital components at the required safety level. The safety cabinet has dual DC motors automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions even without maintenance adjustments.

Transparent toughened sash with conventional weight counter balance system.

 

Detailed Images

Advantages

  • EN12469 certified
  • H14 as per EN-1822 certified HEPA Filter
  • Dual stage filtration system
  • Low heat & low energy consumption
  • Standby mode to economize power consumption
  • Economy mode of operation to reduce energy consumption
  • Vertical airflow direction
  • Class 2 air cleanliness class as per ISO 14644-1
  • Whole unit controlled by a microprocessor controller
  • Magnehelic gauge digital type low- and high-pressure indicator
  • Closing/opening of front door integrated with the UV light ON/OFF
  • Display of life of HEPA filter and UV lamp
  • Intuitive control panel displays valuable safety and performance data with constant read-out of downflow/inflow velocities with digital airflow verification alarm features
  • Timing technology allows users to program timed on/off function
  • Digital display and control panel outside the cabinet with hour counter
  • UV light programming available with timer
  • UV lamp with timer
  • Airflow continuously monitored with sensors and displayed
  • Front panel of the cabinet concave for enhancing user comfort
  • UV light programmable to allow for specific exposure times from 0 to 24 hours
  • UV light automatically switch “OFF” when the sash door is opened & switch “ON” when door is closed to avoid accidental exposure of UV light to the operator
  • Alarms to alert the user if biosafety is compromised
  • Auto speed increase on the opening door for maintaining velocity
  • Automatic component features that adjust blower speed to maintain the optimum airflow in case of filter loading
  • 4 Nos. of castor wheels with lock for easy movement
  • Universal gas valve/port inside the cabinet
  • Drain pan made of stainless steel and spill trough with drain valve
  • Designed to operate at 220-240V,50Hz with single phase power supply
  • A 3-pin 5 A compatible with Indian plug-top electrical outlet inside working chamber

Additional Accessories

  • HEPA filter
  • Gas burner
  • Height adjustable base stand

Technical Data

Specs/Model

SMI-163AB3

SMI-163AB4

SMI-163AB6

External Size (W X D X H)

1030 X 850 X 2100mm

1500 X 850 X 2100mm

1870 X 850 X 2100mm

Internal Size (W X D X H)

900 X 600 X 600 mm

1200 X 600 X 600 mm

1700 X 600 X 600mm

Working Area Height

750mm

750mm

750mm

Maximum Front Sash Opening

520mm

520mm

520mm

Front Sash Opening

200mm

200mm

200mm

Production/ Test Standard

CE / In accordance with EN12469

CE / In accordance with EN12469

CE / In accordance with EN12469

Air Flow Volume (Inflow)

417 CFM

417 CFM

417 CFM

Air Flow Volume (Downflow)

663 CFM

663 CFM

663 CFM

Air Flow Volume (Exhaust)

459 CFM

459 CFM

459 CFM

Downflow Velocity

0.35m/s, 60FPM

0.35m/s, 60FPM

0.35m/s, 60FPM

Inflow Velocity

0.53m/s, 105FPM

0.53m/s, 105FPM

0.53m/s, 105FPM

Front Window 10” sash open

5mm toughened glass with vertical sliding

5mm toughened glass with vertical sliding

5mm toughened glass with vertical sliding

Filter

HEPA filter efficiency of 99.990% efficiency at 0.3 µm particle

HEPA filter efficiency of 99.990% efficiency at 0.3 µm particle

HEPA filter efficiency of 99.990% efficiency at 0.3 µm particle

Noise Level

60 dB

60 dB

60 dB

White Fluorescent light illumination

1200Lux Eco-friendly

1200Lux Eco-friendly

1200Lux Eco-friendly

Display

 Digital Display

Digital Display

Digital Display

Power Sockets

Two (15/5 Amp)

Two (15/5 Amp)

Two (15/5 Amp)

UV Light

20W ; 254nm

20W ; 254nm

20W ; 254nm

Audio-Visual Alarms

Deviation in airflow velocity,

Filter replacement, sash

position, UV life timer, blower failure, window position

Deviation in airflow velocity,

Filter replacement, sash

position, UV life timer, blower failure, window position

Deviation in airflow velocity,

Filter replacement, sash

position, UV life timer, blower failure, window position

Taps

Water Tap : 1

Gas Tap : 1

Vacuum/Air Tap : 1

Water Tap : 1

Gas Tap : 1

Vacuum/Air Tap : 1

Water Tap : 1

Gas Tap : 1

Vacuum/Air Tap : 1

Weight

316Kg

371Kg

390Kg